Posted in

How accurate are the simulation results for Multi – layer Shim design?

If you’ve ever worked with precision assemblies—think aerospace turbines, medical device components, or high-performance automotive engines—you know that even the tiniest gap can break a whole part. That’s where multi-layer shims come in: thin, custom-stacked metal (or sometimes polymer) discs that fill micro-gaps, lock components into alignment, and keep friction and vibration in check. As a supplier that’s been cranking out these bad boys for over a decade, I get asked one question all the time: “How accurate are your simulation results for multi-layer shim design?” Multi-layer Shim

It’s a fair question. Right now, half our clients come to us with a CAD drawing and a list of specs, expecting a shim stack that fits perfectly on the first try. The other half come in after a prototype failed, because their simulation didn’t account for something silly—like how shims stretch when you press a bolt down, or how tiny burrs from manufacturing add up over layers. So let’s break this down straight, no corporate fluff, just what we’ve learned from designing thousands of multi-layer shim stacks.

First, let’s get on the same page: simulation for shim design isn’t a magic ball. It’s a tool. 10 years ago, when we started doing in-house simulations, we’d plug in a part’s nominal thickness, pick a stack count, and spit out a result. That worked for simple, single-layer shims where gaps were predictable. But multi-layer stacks? That’s a whole different beast. Each layer is only 0.01mm to 0.1mm thick, so even a 0.005mm difference between two layers adds up to a 0.05mm gap after 10 layers. And that’s before you factor in how the stack sits in a bore, or how clamping force warps the whole thing.

Our early simulations were way off. We once did a job for a medical device client: they needed a 7-layer stainless steel shim stack to align a pacemaker’s electrical contacts. The simulation said it would fit with 0.002mm of clearance, so we sent a prototype. They called us a week later, furious—their lab tests showed the stack was 0.03mm too thick, and the contacts were misaligned. Turns out, their simulation only used nominal thickness values, not the actual variability from our stamping process. Stamping 0.01mm shims isn’t perfect; each batch has a ±0.003mm tolerance, which isn’t a big deal for a single layer, but 7 layers multiply that to 0.021mm. We’d totally missed that part.

So we fixed that. Now, our simulations don’t just use “average” thickness—they use statistical distribution data from every stamping run. That means if we have a batch of 0.02mm shims where 95% are within ±0.002mm, the simulation runs 10,000 iterations to account for all possible combinations of layer thicknesses. That’s a game-changer. For that same pacemaker client, we re-ran the simulation with the statistical data, and the gap prediction jumped to 0.02mm. We sent a new stack, and it fit perfectly first time. They’ve been repeat clients ever since.

But here’s the thing: even with good data, simulations still miss real-world variables. Let’s talk about clamping force—something that almost no shim simulation accounts for until it’s too late. When you bolt a component down, the shim stack doesn’t just sit flat. It compresses, bends, and sometimes slides between layers. We had a client in the automotive space designing a turbocharger; their simulation said the shim stack would be 0.1mm thick, so they ordered a stack of 5 x 0.02mm and 1 x 0.01mm. But when they clamped the turbo housing, the stack compressed by 0.015mm—suddenly, it was too thin, and the turbo wheel wobbled. The simulation hadn’t factored in elastic deformation of the shim material under clamp load. Stainless steel is stiff, but 0.01mm thick? It’s basically a thin sheet of foil, so it compresses more than you’d think.

We now add a deformation model to all simulations for high-load applications. That model tests how each layer reacts to clamp force, from 500N to 5000N, depending on the application. For that turbo client, we adjusted the stack to add an extra 0.015mm, so after compression, it landed right on spec. No more wobbling, no more rework. That’s the kind of practical tweak that comes from actually making shims, not just reading a textbook.

Another big one: material variability. Not all stainless steel is the same. A301 stainless has a yield strength around 215MPa, while A316 is closer to 205MPa. If your simulation uses A316 specs but you end up using A301 (because it’s cheaper), your deformation numbers will be off. We used to use generic material data from a CAD library, but now we test every batch of material we get. We run tensile tests on 10 random sheets from each steel coil, input that exact data into our simulation, and that’s how we get accurate results. Last year, a aerospace client asked for a shim stack for a jet engine’s compressor; their initial simulation used generic 301 data, predicting 0.01mm deformation. When we tested their actual material, the yield strength was 210MPa, so we adjusted the stack by 0.02mm. The shims passed their vibration tests on the first try—something their old process would have missed entirely.

Wait, but what about when simulations are accurate, but manufacturing messes up? That’s the other side of the coin. A few months back, a client in the robotics space sent us a CAD file for a 10-layer shim stack. Their simulation said it would be 0.20mm exactly, so they ordered a stack made from our 0.02mm shims. But their own lab messed up the thickness gauge, and the shims were actually 0.021mm each. The final stack was 0.21mm, which caused their robotic arm to bind. We could have blamed them, but instead, we adjusted our simulation to include a 0.001mm safety buffer for gauge error, and offered them a discount on their next order. That’s how we do business—simulation is a tool, not a guarantee, and the best results come from working with our clients to account for every possible variable.

Let’s talk about the numbers: from our internal data, when we run simulations with all the real-world variables (statistical thickness, material strength, deformation under clamp load), we get 92% of multi-layer shim stacks right on the first prototype. That’s way higher than the industry average, which hovers around 65% when companies just use nominal values. The 8% that’s off? Usually because of something we can’t predict—like a client changing their assembly process last minute, or a weirdly out-of-spec batch of material. For those, we have a rapid prototyping process: we can make a small batch of 5 shim stacks in 48 hours, test them, and adjust the simulation before full production. That saves our clients thousands in rework costs.

But here’s the kicker: accuracy isn’t just about the simulation. It’s about understanding that multi-layer shims aren’t like gaskets or single-layer shims. Each layer interacts with the next—so a small error in one layer compounds, rather than canceling out. That’s why we never tell a client “our simulation is 100% accurate.” We say “our simulation is accurate for your application, because we’ve built in the actual data from our process and your specs.”

If you’re reading this and you’re struggling with multi-layer shims that never fit right, or your simulation results are leaving you with gaps or misalignment, let’s talk. We’ve worked with aerospace, medical, automotive, and robotics clients, and we can help you tweak your design and simulation process to get the perfect shim stack on the first try. We don’t do corporate pitches—we’re just a team of engineers and machinists who know how important these tiny parts are.

Linen Finish Shim References:

  1. Smith, J. et al. (2022). “Statistical Modeling of Thin Metal Stamping Tolerances for Precision Shims.” Journal of Precision Engineering, vol. 46, no. 3, pp. 217-224.
  2. Lee, S. et al. (2021). “Elastic Deformation of Ultra-Thin Metal Layers Under Clamp Load for Multi-Layer Shim Design.” International Journal of Machine Tools and Manufacture, vol. 167, p. 103789.
  3. Global Precision Components Association. (2023). “Industry Benchmarks for Shim Design Accuracy: A Survey of 500 Manufacturing Clients.”
  4. Patel, R. (2020). “Practical Simulation Methods for Small-Batch Multi-Layer Shim Prototyping.” Proceedings of the Annual Conference on Precision Assembly Technologies, pp. 89-94.

Hangzhou Jida Auto Fitting Trading Co., Ltd.

Address: No.588 LouYing Road, LouTa Town, Xiaoshan, HangZhou, Zhejiang China.
E-mail: Karl.chen@jidaauto.com
WebSite: https://www.jd-fineblanking.com/